VP-790 Protocol API Functions 85
2.77.3 358BbyOsdOutputFormatSave
API index: 325
Saves the Output Mode Resolution setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.78 86BOverscan
2.78.1 359BbyOsdOverscanSet
API index: 2944
Sets the input overscan percentage.
Input Parameters
Name Type Range Description
Value UWORD32 0: 0%
1: 2.5%
2: 5%
3: 7.5%
Overscan value
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.78.2 360BbyOsdOverscanGet
API index: 2945
Retrieves overscan setting from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Standard
1: Full Screen
2: Crop
3: Anamorphic
Overscan value