VP-790 Protocol API Functions 79
2.71.4 340BbyOsdEnableGet
API index: 3374
Retrieves the OSD enabling setting.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: off
1: on
Determines if OSD is on or off.
2.71.5 341BbyOsdEnableSave
API index: 3375
Saves the OSD enabling setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.72 80BOSD Language
2.72.1 342BbyOsdLanguageSet
API index: 445
Sets the OSD language.
Input Parameters
Name Type Range Description
Value UWORD32 0: English AE
1: English BE
2: German
OSD Language
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise