VP-790 Protocol API Functions 63
2.54 62BLED Screen Window Size Enabling
2.54.1 292BbyOsdOutWinSizeEnableSetSave
API index: 3306
Enable Window Size Controls and save on/off setting to the SPD.
Input Parameters
Name Type Range Description
Value UWORD32 0: off
1: on
Enables or disables the Window Size
Controls.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.54.2 293BbyOsdOutWinSizeEnableGet
API index: 3307
Retrieves the Window Size Controls enable/disable setting.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: off
1: on
Retrieves the Window Size Control
enable/disable setting.
2.55 63BLoad profile from
2.55.1 294BbyOsdProfileLoadFrom
API index: 2957
Copies all settings from a given profile into the current one.
Input Parameters
Name Type Range Description
Value
UWORD32
0 .. 3
Profile number to load from
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code
otherwise