VP-790 Protocol API Functions 107
2.103 111BS-Curve Value
2.103.1 426BbyOsdEdgeBlendScurveValueSet
API index: 3115
Sets the S-curve value.
Input Parameters
Name Type Range Description
Value UWORD32 0x10-0x19 S-Curve power value. The power
ranges from 1.0 to 2.5. The value set
is the in multiples of 1/10.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.103.2 427BbyOsdEdgeBlendScurveValueGet
API index: 3116
Retrieves the S-curve value.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x10-0x19 S-Curve power value. The power
ranges from 1.0 to 2.5. The value
retrieved is in multiples of 1/10.
2.103.3 428BbyOsdEdgeBlendScurveValueSave
API index: 3117
Saves the number from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise