110 VP-790 Protocol - API Functions
2.106 SDI Output Data Map
2.106.1 byOsdSdiDataMapSet
API index: 3265
Sets the SDI output mode.
Input Parameters
Name Type Range Description
Value UWORD32 0: Level A
1: Level B
2: 4:2:2 YCbCr
3: 4:4:4 YCbCr
4: 4:4:4 RGB
Sets the SDI output mode.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.106.2 byOsdSdiDataMapGet
API index: 3266
Retrieves the SDI output mode setting from cache or from the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Level A
1: Level B
2: 4:2:2 YCbCr
3: 4:4:4 YCbCr
4: 4:4:4 RGB
SDI output mode setting.
2.106.3 byOsdSdiDataMapSave
API index: 3267
Saves the SDI output mode setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise