Kramer-electronics VP-790 Instrukcja Użytkownika Strona 23

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 126
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 22
VP-790 Protocol API Functions 19
2.8 16BAnnounce Data
2.8.1 157BbyOsdSetAnnounceAuxData
API index: 4210.
Defines a string to be sent.
Input Parameters
Name Type Range Description
Value STRING String with 16 ASCII
characters /0
terminated
Port
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.8.2 158BbyOsdGetAnnounceAuxData
API index: 4209
Retrieves the string being sent.
Input Parameters
Name Type Range Description
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value STRING nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Netmask
2.8.3 159BbyOsdSaveAnnounceAuxData
API index: 4208
Saves the string from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise