28 VP-790 Protocol - API Functions
2.18 CCS
2.18.1 byOsdCCSSet
API index: 2975
Switches CCS (Cross Colour Suppression) filter on/off for the CVBS input.
Input Parameters
Name Type Range Description
Value
UWORD32
0: Off
1: On
CCS switch
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF
0 if successful, error code
otherwise
2.18.2 byOsdCCSGet
API index: 2976
Retrieves the status of the CCS from either cache or the SPD.
Input Parameters
Name Type Range Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status
BYTE
0x00-0xFF
0 if successful, error code
otherwise
Value UWORD32 0: Off
1: On
CCS switch
2.18.3 byOsdCCSSave
API index: 2977
Saves the status of the CCS from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise