34 VP-790 Protocol - API Functions
2.24 CTI Level
2.24.1 byOsdSTICTISet
API index: 611
Sets the level of the CTI (chroma transient improvement) filter.
Input Parameters
Name Type Range Description
Value UWORD32 0: Off
1: Low
2: High
CTI value
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.24.2 byOsdSTICTIGet
API index: 613
Retrieves the level of the CTI filter from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Off
1: Low
2: High
CTI value
2.24.3 byOsdSTICTISave
API index: 612
Saves the level of the CTI filter from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise