116 VP-790 Protocol - API Functions
2.112 TRNR
2.112.1 byOsdTRNRSet
API index: 239
Sets the level of the TRNR (temporal recursive noise reduction) algorithm.
Input Parameters
Name Type Range Description
Value UWORD32 0: Off
1: Low
2: Medium
3: High
TRNR value
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.112.2 byOsdTRNRGet
API index: 241
Retrieves the level of the TRNR from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Off
1: Low
2: Medium
3: High
TRNR value
2.112.3 byOsdTRNRSave
API index: 240
Saves the level of the TRNR from cache into the SPD.
Input Parameters
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise