VP-747 - VP-747 Communication Protocol 55
Set Commands (F = Function)
Control Type Function Param 1 Param 2 Param 3 Param 4 Description
Set Get
0 - 242 - - - -
Program Geometry
Diagonal Projection
Reset
0 1 243 -20 ~ 20 - - -
Program Geometry
0 1 244 -180 ~ 180 - - -
Program Geometry
0 - 245 - - - -
Program Geometry
0 1 271
0: Cut
1: Fade
2: Diagonal
3: Wipe
4: Circle
5: Square
6: Corner
7: Chessboard
- - - Transition Effect
0 1 272
0:Swap
- - - Transition Mode
0 1 273 1 ~ 5 - - - Transition Speed
0 1 274
0 = no damping
1 = damping with a
maximum jump size of
10 steps
2 = damping with a
maximum jump size of
5 steps
3 = damping with a
maximum jump size of
3 steps
4 = damping with a
maximum jump size of
Transition Damping
0 1 275
0: Top left
1: Bottom left
2: Top right
- - -
Transition Effect Option
- Diagonal
0 1 276
0: Left to right
1: Right to left
2: Up
3: Down
- - -
Transition Effect Option
- Wipe
0 1 277
0: In
- - -
Transition Effect Option
0 1 278
0: In
- - -
Transition Effect Option
0 1 279
0: Top left
1: Bottom left
2: Top right
- - -
Transition Effect Option
- Corner
0 1 280
0: In
1: Out
- - -
Transition Effect Option
- Chessboard
0 1 282 0: Off
1: On
T-Bar Optimization
0 1 283 16 ~ 240 Checksum - -
T-Bar Command
Checksum Rule:
1. Set Command Only
2. Checksum = (Control
Type + Function +
Param1) % 256
3. Example : Y 0 283
Komentarze do niniejszej Instrukcji