12 VP-460 - The OSD Menu
Note that:
• A selected parameter that turns gray becomes valid immediately (there is no
need to press Enter to save the changes)
• Exiting the menu saves the parameter to the memory
• Data is saved per window and per input (to a dedicated input + window
memory), as applicable
The control buttons let you control the VP-460
via the OSD menu. Press the:
• MENU (or ) button to enter the menu, exit the menu, and when in the OSD
menu, move to the previous level and change menu settings in the OSD
screen.
• ENTER (or ) button to access sub-menu items
• Arrow buttons to move through the OSD menu
• Up or down arrows to change settings (changes are immediate)
Note that when the exiting menu, all the changes are automatically
saved to the non-volatile memory.
The default OSD timeout is set to 30 seconds and can be changed
(see
Section 5.8
5.1.1 OSD Control Icons
).
The following three icons: M, P, and E are included to indicate when functionality
applies to the Main window, the PiP Window or the entire system:
• M for Main Window Control
• P for PiP window Control
• E for Entire System Control