RB-6 - RB-6 Communication Protocol
12 RB-6 Communication Protocol
The RB-6 supports Kramer Protocol 3000.
Go to our Web site at http://www.kramerelectronics.com to check for
the latest RB-6 communication protocol.
With Kramer Protocol 3000 you can control a device from any standard terminal
software (for example, the Windows
®
HyperTerminal Application).
This RS-232/RS-485 communications protocol uses a data rate of 115,200 baud,
no parity, 8 data bits and 1 stop bit.
12.1 Syntax
12.1.1 Host Message Format
12.1.1.1 Simple Command
Command string with only one command without addressing:
Command SP Parameter_1,Parameter_2,…
12.1.1.2 Command String
Formal syntax with commands concatenation and addressing:
Command_1
Parameter1_1,Parameter1_2,…|
Command_2
Parameter2_1,Parameter2_2,…|
Command_3
Parameter3_1,Parameter3_2,…|…
12.1.2 Device Message Format